This object is the main node of the system tree and includes all the main features and data that describe the project. All other objects, which represents the configurable services provided by the server, can be added to the project by right clicking on this node.
By selecting the object, the following properties will be displayed in the grid below:
Commands sent to the object and recallable from other objects:
This command is used to send a bit value; adjust the ”KNX group” and ”KNX value” (0 or 1) parameters displayed on the right.
Send a byte value; adjust the ”KNX group” and ”KNX value” (from 0 to 255) parameters.
Send a float 2 byte value; adjust the ”KNX group” and ”KNX value” parameters.
Send a float 4 byte value; adjust the ”KNX group” and ”KNX value” parameters.
Send a string 14 byte value; adjust the ”KNX group” and ”KNX value” parameters.
Pause the system for a specified time interval configurable by adjusting the ”Interval” parameter.
This command allows to configure a specific project page that will be recalled on all clients; adjust the ”Function” and ”Page” parameters.
This command allows to configure a specific project page that will be recalled on a specific client; adjust the ”Function” and ”Page” parameters.
This command allows to send push notifications on the desired client; adjust the ”Message” parameter to define the notification content.
This command allows to launch an .exe file directly from the ThinKnx application on all Players for Windows; adjust the ”Command” parameter.
This command allows to launch an .exe file directly from the ThinKnx application on a specific Player for Windows; adjust the ”Command”.
This property allows to launch a specific app on iOS devices directly from the ThinKnx app by typing the related url in the ”URL used to recall iOS app” parameter (f.e. http//www.google.com will automatically browse the google safari page).
This command allows to send an email message using a default ThinKnx account; define the email subject, content and recipients by adjusting the parameters on the right.
This command allows to send a DTMF tone or a sequence of tones while an intercom call is running on the client.
This object contains all KNX groups configured in the ETS software. It simplifies visualisation and selection of these groups within the Configurator thanks to a tree displaying. Following properties are displayed in the grid below:
Launch ETS, then right click on ”main groups” (ETS3) or ”Group Addresses” (ETS4) and select the ”export group addresses” option. With ETS 3 use default export parameters, in ETS 4 select CSV format and activate the ”Export header information” flag.
Figure 4.1: ETS 3 export parameters |
With ETS 4 and later versions, the project can be exported in OPC.
From the ETS application, click on “Other → Export OPC”: the generated “.esf” file can be imported in the Configurator at a later time.
This service allows to define a list of actions to be performed by the server on user’s demand or depending on a specific setting. These actions can be specified by the installer directly in the Configurator or in the client application by the user.
Commands sent to the object and recallable from other objects:
Launches the selected scene.
Stops the selected scene.
This server service allows the user to program on/off KNX commands (switch objects) using client applications; it is also possible to memorize the temporization on server. Different switches can be associated to the same calendar.
This object allows to control HVAC devices: a HVAC controller can control more than one device commanded using the same connection type.
Select the ”Devices” property and click on the button displayed on the right to open the devices editor window; click on ”Add” button and adjust the properties in the grid.
This server service allows the user to program until six daily temporisations for a switch object. The server checks events planning so that value 1 is sent to the switch object at the preset time.
A single Voip PBX object can be added to the system.
Daily and weekly boiler programs can be configured on the server using this object.
PBX internal to ThinKnx servers (supported by Compact and Micro). This object allows to configure the PBX (extensions, ring groups and door stations).
Click on the button displayed on the right to open the PBX users editor window, then click on ”Add” and adjust the properties in the grid:
Click on the button displayed on the right to open the ring groups editor window, then click on ”Add” and adjust the properties in the grid:
Click on the button displayed on the right to open the intercom devices editor, click on ”Add” and adjust the properties in the grid:
The Irrigation object allows to manage different zones of the irrigation system, each of them controlled by a different KNX group. These zones can be combined for creating different irrigation programs, directly in the client application.
Click on the button displayed on the right to open the zones editor window, then click on ”Add” and adjust the properties in the grid:
This object allows the user to control a RGB lamp and create sequences of colors. The bus types supported are: KNX, Modbus and Philips Hue.
Commands sent to the object and recallable from other objects:
Starts the preconfigured colour sequence in a random order; adjust the ”Time” parameter on the right to select the time interval between two consecutive colours.
Repeats the preconfigured colour sequence following the defined order; adjust the ”Time” parameter on the right to select the time interval between two consecutive colours.
Stops the repetition of the colour sequence and turns the RGB lamp off.
This object is needed to configure SMTP server parameters to send email messages from the server (used to send alerts, reports etc.).
Commands sent to the object and recallable from other objects:
Allows to send an email message using a customisable personal account; define the email subject, content and recipients by adjusting the parameters on the right.
This server service allows to start a web server to control the plant from the web.
Click on the button displayed on the right to open the users editor window, click on ”Add” and adjust the properties in the grid:
This object is particularly useful to configure a list of actions that can simulate the presence of people even if the house is empty (f.e. turning lights on, starting the audio system etc.).
Click on the button displayed on the right to open actions editor window, click on ”Add” and then adjust the properties in the grid:
Commands sent to the object and recallable from other objects:
Starts the presence simulator sequence of actions.
Ends the presence simulator sequence of actions.
This service calculates sun position (sunset, sunrise, azimuth and elevation) starting from the geographic position of the plant. It is also possible to associate actions to sun positions.
To define an action to perform when a predefined sun event occurs, click on the button displayed on the right of the ”Sun Actions” property, click on ”Add” and then adjust the properties in the grid:
This object is used to integrate the central alarm in the project; it allows the server to arm or disarm the central, to read partitions or sensor status and to singularly control them. All alarm panels integrated in the system provide the user with the same graphical effect; they can be selected from the following list of models:
The system allows to manage Kyo8, Kyo16 and Kyo32 panels. Those panels can establish only a serial connection with ThinKnx system using a null-modem cable. Partitions, in ThinKnx, take numbers starting from 0 for the first one; sensors take numbers starting from 0 for the first one as well.
To interact with a TecnoAlarm device, the licence Tecnoout must be enabled on the alarm device following the manufacturer’s instructions. Furthermore, through the Centro software, the alarm device must be configured on the network as illustrated in following pictures.
In the “Extra” tab, check the box corresponding to “Tecnoout” and specify the correct port (10500 is recommended) and a password with 16 characters.
In the “LAN” tab, configure the network settings.
The port specified in the “Extra” tab must be different from those specified in the “Server” tab, even if ports specified in the “Server” tab are unchecked.
Parameters for alarm device can be set just during the first configuration. To change those values a complete reset of the device is needed.
Click on the button displayed on the right to open partitions editor window, click on ”Add” and then adjust the properties in the grid:
Click on the button displayed on the right to open sensors editor window, click on ”Add” and then adjust the properties in the grid:
[comb]
The ”Combination” object allows to perform logical operations (AND, OR, XOR) on the values coming from KNX groups and to send the result to another KNX group.
In order to set up the list of the inputs of the combination, select the ”Inputs” property and click on the button displayed on the right.
In the displayed window, in order to add a new input, click and the ”Add” button below. An ”Input” object will be added to the list; select it and adjust the properties on the right.
The ’Filter’ object allows to perform operations on the value of an input KNX group and to send the result with an optional delay to an output KNX group. To set up the ”Filter” object, select from the system tree and adjust the properties displayed in the grid below.
This object, given an input and two outputs, allows to choose, through a control bit, the output which the input value has to be assigned to.
In order to set up the ’Multiplexer’ object, select it in the system tree and adjust the properties displayed in the grid below.
This object, given n inputs and n outputs, to select an input with a 1 byte selector and send it on an output chosen with a 1 byte selector.
Click on the button displayed on the right to open inputs editor window, click on ”Add” and then adjust the properties in the grid:
Click on the button displayed on the right to open outputs editor window, click on ”Add” and then adjust the properties in the grid:
This object allows to calculate weighted sums between the bit values of specific input KNX groups and to assign the result expressed in bytes to an output KNX group. Therefore, the output value is:
C - p1 . v1 + p2 . v2 + … + pk . vk
where p1 is the load (from 0 to 255) associated to the addend v1 that is the value 0 or 1 coming from the input KNX group. It’s particularly useful in case it’s requested to modulate a KNX command through a byte because it allows to associate a different weight to each addend.
In order to set up the ’Linear combination’ object, select it in the system tree and adjust the properties displayed in the grid below.
In order to set up the addends of the sum, select the property ’Addends’ and click on the button displayed on the right. In the displayed window, to add a new addend, click on the ’Add’ button below. An object ’Addend’ is added to the list, select it and adjust the properties on the right.
The ”Complex maths expressions” object represents a collection of logical and arithmetical operations that can be written to elaborate values coming from different KNX groups. It’s possible to write expressions for the calculation of sums, balances, means, absolute values and analogical values, such as temperature and consumption, coming from KNX commands.
To write an expression, add the ”Complex maths expressions” object, select it and adjust the properties displayed in the grid below.
Click on the ”Add” button in the displayed window. An ”Expression” object is added to the list, select it and adjust the properties on the right.
To enter the math expression click on the button on the right of the property “Expression” in the “Expressions Editor” window, which contains the list of all the expressions. In the single “Expression Editor” window the math expression can be directly added, with the desired variable names.
Clicking the “Check” button variables are generated and for each variable following properties can be set.
The change of the expression doesn’t involve of the previously set properties of the variables. Renaming a variable involves the cancellation of the old one and the creation of a new one: the new variable doesn’t acquire the properties of the old one.
Whenever the text of the expression is changed, click on the ”Check” button before clicking on ”Ok”. Not doing so, the variables do not generate and the expression is not saved.
The expression can contain mathematical operators such as +, -, *, /, > (greater-than), < (less-than), = (equal), := (assignment), <> (different) and logical operators such as ”AND” and ”OR”. Decimals have to be expressed with ”.” symbol, for example 0.9, 1.5, 20.05. Each line have to end with ”;” symbol. Is possible to include mathematical functions such as mean, absolute value and rounding. For a complete list of functions with related syntax, click on the ”?” button below.
This feature allows to export a list of expressions previously created in a project and import it in another project.
To export the expressions list, open the expressions list editor window by clicking on the button displayed on the right of the ”Expressions” property. Click on the ”Export” button and choose the path of the xml file that will be created, in this way the list of expressions will be saved outside the Configurator.
To import the expressions list in a project, open the expressions list editor window by clicking on the button displayed on the right of the ”Expressions” property. Click on the ”Import” button and select the xml file previously saved and click on OK button to confirm. A list of expressions will appear in the editor window.
This object represents a collection of values stored in the server and associated to a KNX group. Through these variables it is possible to store, for example, the results of mathematical or logical operations and make them available on KNX through a group address. It is possible to choose if the value will be stored on the server in a persistent way, which means that the value will be available also after the server reboot.
In order to add a variable the variable editor must be opened. Click on the ”Add” button to define following properties:
This object represents a service to store data coming from the plant on a cloud database. All these data will be accessible through the Chart interface object.
This objects works correctly only if the ThinKnxCloud service is enabled and configured!
A database variable is an object which represent the value to store in the database. Clicking on the button on the right of the Values Collection property. Add a new value with the Add button and edit its properties to configure the saving modalities:
Since the quantity of data storable for each server in the cloud database is limited, it is highly recommended to use the filter policies.
This object defines a values collection to be saved in the internal memory according to time intervals defined by the installer. This values are sent via mail and optionally organised in charts.
Click on the button displayed on the right to open recipients editor window, click on ”Add” and then adjust the properties in the grid:
Click on the button displayed on the right to open values editor window, click on ”Add” and then adjust the properties in the grid:
This object allows the server to control Philips Hue lamps. It is possible manage shades of white or all the colours in the spectrum from the configurator.
Clicking on the button on the right of the IP address property or MAC address it is possible to open the Hue Bridge Finder window. In this window, the configurator searches for Hue Bridges connected to the local network and displays them in a list. Every bridge can be ”Authorized” or ”Not Authorized”:
Clicking the ”Select bridge” button the selected bridge is associated to the Hue gateway object.
In the ”Hue Bridge Finder”, under each Authorized bridge node, there is a list of all the lights and groups configured in the Bridge. With a right click on the bridge is possible turn on or turn off all the lights, refresh the properties read from the bridge and create a new group of lights. Selecting a lamp node, in the property grid on the right, the properties configured in the bridge are displayed:
Every Hue lamp node has a child node, which is the lamp status node. By selecting it a list of editable properties will be displayed:
After editing these properties, to save them in the Hue Bridge, click the ”Save Properties” button.
The Configurator allows to create Hue Groups directly from the ”Hue Bridge Finder” window: right click on the Bridge node and select ”Create new lights group” in the menu that appears. This action adds a child node to the Groups node, selecting the group properties will be displayed:
Every Hue group node has a child node, which is the group status node. The properties of the status node are the same of the single Hue lamp but they apply to all the lamps of the group.
All the properties listed in the ”Hue Bridge Finder” window are used to test the Hue Bridge configuration (or edit it) but they don’t represent the real configuration needed by ThinKnx server to control the lights. The real configuration is made by adding a controlled element. Please refer to the chapter below.
Clicking on the right button of the Controlled elements property, a window will be displayed. Click on the ”Add” button, select the added object and adjust its properties:
Commands sent to the object and recallable from other objects
Turn on or off the Hue element. Set 1 as parameter turn on the element, while 0 turn off the element.
set the desired value for the dimmer through a single parameter which can assume a value between 0 and 255.
Set the element color temperature. A single parameter must be set with a value within 0 and 255, where 0 corresponds to Cold White (6500 K) and 255 correspond to Warm White (2000 K).
Set the element RGB color through the definition of three parameters for Red, Green and Blue. Each color can assume a value between 0 and 255.
It allows the bidirectional connection of MyHome BTicino plants to KNX plants. Through easy-to-fit tables it is possible to set matching among the messages coming from the two worlds.
This server service reads the electrical energy consumption in a specific plant point from KNX group. Basing on thresholds previously set by the installer, the server can disconnect the load for a predetermined time interval or notify the user.
Click on the button displayed on the right to open the loads editor window, click on ”Add” and adjust the properties in the grid:
It allows to integrate Modbus devices.
It allows to integrate Z-Wave devices. Without any gateway, the result is a reliable and easy-to-use system with a bidirectional connection between Z-Wave and other standards such as KNX.
Click on the button on the right of the property Nodes. It will appear the ZWave node collection editor.
Clicking on Read nodes from controller the system will receive the list of nodes from the Z-Wave controller (internal or external).
To save changes click on the button Save Nodes to the controller
Clicking on the Close without saving button all unsaved changes will be lost.
Thinknx integration with iBezel. KNX groups can be associated with iBezel leds and movements.
Click on the button on the right ”iBezel device”. On the device editor click on the ”Add” button and define following properties:
This service allows the server to function as gateway, performing actions based on conditions defined by the installer on KNX groups. For each KNX value three conditions can be applied so that three different actions can be defined.
Click on the button displayed on the right to open the actions editor window, click on ”Add” and adjust the properties in the grid:
This service allows the server to send messages using the external service Skebby. SMS can be used to send notifications, alerts, etc.
Commands sent to the object and recallable from other objects:
Sends an SMS. In the parameters specify the SMS content and the recipients’ number; the number should be preceded by the national code without leading + nor 00.
This object allows bidirectional connection of Lutron plants to KNX plants. The integration allows to associate KNX groups to Lutron lights, making the devices in the Lutron plant controllable from KNX buttons or supervision.
This object represents the interface between ThinKnx system and a third-party device connected through serial port. It makes possible to send commands through the serial port to the device.
Commands sent to the object and recallable from other objects:
Sends a string to the serial port without carriage return; adjust the parameter on the right to specify the string text.
Sends a string to the serial port with carriage return; adjust the parameter on the right to specify the string text.
Sends a hexadecimal string to the serial port without carriage return; adjust the parameter on the right to specify the string text. The string command has to be converted in hexadecimal, and each byte must be separated by a space. In case of absence of CR, also the termination characters must be expressed in hexadecimal.
Sends a hexadecimal string to the serial port with carriage return; adjust the parameter on the right to specify the string text. The string command has to be converted in hexadecimal, and each byte must be separated by a space.
Depending on the server you are going to use, the serial port number should be set according to the following settings:
This object is a server service that allows to send GET and POST requests, and strings on TCP or UDP sockets.
Commands sent to the object and recallable from other objects:
Allows to send a GET; adjust the ”URL” parameter on the right to specify the url.
Allows to send a GET; adjust the ”URL” parameter on the right to specify the url and type in the login parameters required for the authentication to the server.
Allows to send a POST; adjust the ”URL” parameter on the right to specify the url.
Allows to send a POST; adjust the ”URL” parameter on the right to specify the url and type in the login parameters required for the authentication to the server.
Allows to send a string to a TCP socket without carriage return; adjust the parameters on the right to specify the string text and type in the IP address and port of the server.
Allows to send a string to a TCP socket with carriage return; adjust the parameters on the right to specify the string text and type in the IP address and port of the server.
Allows to send a hexadecimal string to a TCP socket without carriage return; adjust the parameters on the right to specify the string text and type in the IP address and port of the server. The string command has to be converted in hexadecimal, and each byte must be separated by a space. In case of absence of CR, also the termination characters must be expressed in hexadecimal.
Allows to send a hexadecimal string to a TCP socket with carriage return; adjust the parameters on the right to specify the string text and type in the IP address and port of the server. The string command has to be converted in hexadecimal, and each byte must be separated by a space.
Allows to send a string to a UDP socket without carriage return; adjust the parameters on the right to specify the string text and type in the IP address and port of the server.
Allows to send a string to a UDP socket with carriage return; adjust the parameters on the right to specify the string text and type in the IP address and port of the server.
Allows to send a hexadecimal string to a UDP socket without carriage return; adjust the parameters on the right to specify the string text and type in the IP address and port of the server. The string command has to be converted in hexadecimal, and each byte must be separated by a space. In case of absence of CR, also the termination characters must be expressed in hexadecimal.
Allows to send a hexadecimal string to a UDP socket with carriage return; adjust the parameters on the right to specify the string text and type in the IP address and port of the server. The string command has to be converted in hexadecimal, and each byte must be separated by a space.
Allows to send a SOAP request; adjust the parameters on the right to specify the destination URL, the SOAP envelope and the SOAP action of the request.
Serial interface available in the new meters in the Netherlands.
The Tester object allows to perform some tests (e.g. ping) and send commands to the plant depending on the result of the test.
To open the ”Test Editor”, click on the button next to the property Tests.
Clicking on the ”Add” button, a new test will be added and will appear on the left column.
To delete a test, select it in the left column and then click on the ”Remove” button.
Selecting a test on the left column a list of properties will appear on the right part of the window, which are:
If the “Test type” is set to “Ping Ethernet Device”, “Test TCP Port” or “Test UDP Port” the following properties will appear:
If the “Test type” is set to “Test TCP Port” or “Test UDP Port” the following property will appear:
If the “Test type” is set to “Ping KNX Device” the following property will appear:
This object allows to interface a video matrix with the system through serial or tcp/ip.
Commands sent to the object and recallable from other objects:
Associates a specified input with a specified output of the matrix; input and output numbers can be specified by adjusting the ”Input Number” and ”Output Number” on the right.
Disconnects a specified input from the previously specified output of the matrix; input and output numbers can be specified by adjusting the ”Input Number” and ”Output Number” on the right.
Resets all the previously configured connection between inputs and outputs of the video matrix.
This object allows to interface a video matrix with the system through serial or TCP/IP.
Commands sent to the object and recallable from other objects:
Associates a specified input with a specified output of the matrix; input and output numbers can be specified by adjusting the ”Input Number” and ”Output Number” on the right.
Disconnects a specified input from the previously specified output of the matrix; input and output numbers can be specified by adjusting the ”Input Number” and ”Output Number” on the right.
Resets all the previously configured connection between inputs and outputs of the audio matrix.
Temporarily mutes a selected output; several output numbers, separated by a comma, can be typed in the ”Output number” parameter. The ”Mute” bit value can be adjusted in the related parameter as well.
Turns up the volume of a specified output (several output numbers, separated by a comma, can be typed in the ”Output number” parameter).
Turns down the volume of a specified output (several output numbers, separated by a comma, can be typed in the ”Output number” parameter).
Configures a specified volume value for the selected output; the volume value and the output number(s) can be defined by adjusting the parameters on the right.
This object is required to interface video projectors using a serial.
Commands that can be recalled from other objects:
Change channel on the TV to the desired number.
Set the video source.
Set mute or unmute.
Turn on the device or put it in standby.
Set the volume
Raise the volume
Lower the volume
This object allows to interface Home Theater plants using serial or tcp/ip.
Commands that can be recalled from other objects:
Power on or standby the device.
Mute or unmute the main output.
Enable or disable the subwoofer.
Enable or disable the OSD.
Raise the main output volume
Lower the main output volume
Set the main output volume
Raise low frequencies for the selected output.
Lower low frequencies for the selected output.
Raise high frequencies for the main output.
Lower high frequencies for the main output.
Move OSD up
Move l’OSD down
Move l’OSD right
Move l’OSD left
Select source for the main output.
Select audio source for main source.
Select video source for main source.
Read tuner frequency.
Read tuner station.
Tuner frequency up.
Tuner frequency down.
Change to next preset.
Change to previous preset.
Tuner auto search.
Tuner stop search.
Press Enter button on OSD.
Select digital mode for main output.
Select surround mode for main output.
This object allows to control Sonos devices from server. They are interfaced by LAN network but, since the server function as KNX gateway, Sonos can be controlled also from KNX plates and not only from client applications.
Commands sent to the object and recallable from other objects:
This command allows to play the device.
This command allows to stop the device.
Turns the volume up.
Turns the volume down.
Skips to the next track.
Returns to the previous track.
Configures a specified volume value for the device; the volume value can be defined by adjusting the parameters on the right.
Mutes the device; the bit value for the mute state can be defined by adjusting the related parameter on the right.
Plays audio from any device connected using a jack.
Plays audio files from the internet; the file url can be defined by adjusting the parameter on the right.
Plays audio from a streaming webradio: the streaming url can be defined by adjusting the parameter on the right.
This object represents the ThinKnx multiplayer integration, a customised version of xbmc; it allows to associate a list of commands with interface objects.
Commands sent to the object and recallable from other objects:
Simulates the $\uparrow$ command.
Simulates the $\downarrow$ command.
Simulates the $\rightarrow$ command.
Simulates the $\leftarrow$ command.
Select the current object in the user interface. (It simulates the ”OK” or ”Enter” command)
Return to the previous page; it simulates the ”Return” or ”Back” command.
Visualise the current object menu; it simulates the ”Menu” button.
Displays a pop-up with the information related to the current program; it simulates the ”Info” button.
Redirects to the GUI homepage; it simulates the ”Home” button.
Visualise a pop-up with the on-screen display for the current player.
Launches a specified file; the file path can be specified by adjusting the ”File path” parameter on the right.
Play or pause the current player.
Stops the player.
Skips the current track and directly play the next one.
Skips the current track and directly play the next one.
Fast forward the current playing element.
Fast backward the current playing element.
Turns the volume up.
Turns the volume down.
This object represents the complete integration of Sonos systems in ThinKnx, it allows to control and receive feedbacks from Sonos players directly through network without creating more traffic on KNX. In this way, all the commands and feedbacks can be available on KNX only if the installer really need them.
Click on the button displayed on the right of the Players property to open the players editor window. By clicking on ”Add” button, the Configurator will automatically start to search for Sonos Player in the local network and it will display them in a list. If the player to add is in the list, select it and click on ”Add Player” to add it to the Players list. Otherwise, if the player isn’t in the list, click ”Search” to restart the automatic research or click on ”Create Player” to add to the list an empty Player object. For each player it is possible to edit the following properties:
The Configurator allows to define groupings (called Topologies) among Sonos Players and to recall them directly from KNX. To create a topology, click on the button displayed on the right of the Topologies property to open the topologies editor window, click on ”Add” and adjust the properties in the grid:
Commands sent to the Sonos Player and recallable from other objects:
Allows to set the Play status on the Sonos Player.
Allows to set the Stop status on the Sonos Player.
Allows to increase the Sonos Player volume.
Allows to decrease the Sonos Player volume.
Allows to directly set the value of the volume of the Sonos Player; the volume value [0-100] can be adjusted by editing the parameter on the right.
Allows to skip to the next track in the Sonos Player queue.
Allows to skip to the previous track in the Sonos Player queue.
Allows to set the Mute status on the Sonos Player; the parameter on the right indicates whether to Mute (1) or Unmute (0) the device.
Starts playing from Audio-in source.
Starts playing from the Audio-in source of a different player; to specify the player adjust the parameter on the right specifying the unique identifier of the source player (refer to Sonos Player properties).
Starts playing from a network file source; the url of the file source must be adjusted in the parameter on the right, using the format //192.168.2.5/Music/abc.mp3
Starts playing from a streaming source; the streaming url must be adjusted in the parameter on the right, using the format //myradiostream.com/stream.pl
Allows to set the playing modality; the parameter on the right indicates whether to Enable (1) or Disable (0) the Repeat modality.
Allows to set the playing modality; the parameter on the right indicates whether to Enable (1) or Disable (0) the Shuffle modality.
Recalls the playlist to play; the parameter on the right indicates the number of the desired playlist. This command only works if the playlist’s name in Sonos starts with “Num -” where Num is the number used to recall the playlist.
Recalls the playlist to play; the parameter on the right indicates the name of the desired playlist. This command only works if the playlist’s name in Sonos is equal to the specified parameter.
Recalls the favorite to play; the parameter on the right indicates the number of the desired favorite. This command only works if the favorite’s name in Sonos starts with “Num -” where Num is the number used to recall the favorite.
Commands sent to the Sonos Topology and recallable from other objects:
Creates the grouping of players as specified in the Sonos Topology properties.
This object allows to control an IR Transmitter device integrated into the LAN network. It can be interfaced with Ethernet, Ethernet PoE and Controller LAN devices.
Click on the button displayed on the right to open the actions editor window, click on ”Add” and adjust the properties in the grid:
This feature allows to export a list of IR commands previously created in a project and import it in another project.
To export the commands list, open the commands editor window by clicking on the button displayed on the right of the ”IR commands” property. Click on the ”Export” button and choose the path of the xml file that will be created, in this way the list of IR commands will be saved outside the Configurator.
To import the commands list in a project, open the commands editor window by clicking on the button displayed on the right of the ”IR commands” property. Click on the ”Import” button and select the xml file previously saved and click on OK button to confirm. A list of commands will appear in the editor window.
During the import process, if the ”Remotes directory” property of the ”IR transmitter” object isn’t set, the commands will be added to the list with the prefix ”***” in the name and only the command alias will be set.
Commands sent to the object and recallable from other objects:
Allows to create sequences using the commands previously configured in the relates system object properties (please refer to the dedicated section). To create a sequence select the desired command from the list and the click on ”Enqueue”; the ”Make pause” item can be added to the sequence in order to grant a better reception. The sequence displayed in the box below can be edited by deleting single items or moving them by clicking on ”Up” and ”Down” buttons. By checking the ”Output option” item, the same command can be sent to different outputs of the same IR device.